Select Page

Extreme Duty Breathers

The Des-Case Extreme Duty (XD) desiccant breather has excellent vibration and impact resistance, can withstand broad temperature ranges, has expansive chemical compatibility, and features quality check valve technology while still accommodating higher air flow. The Extreme Duty breather also has the best filter efficiency of any Des-Case breather―down to 0.3µ absolute (β0.3≥200).

 Compare Models

Try One on Us

Request your complimentary disposable desiccant breather today. 

Specifications

Download XD Series Technical Specs
   

Model Specs

Model Unit Height (in / mm) Unit Diameter (in / mm) Connection Size Amount of Silica Gel (lbs / kg) Adsorption Capacity (fl oz / ml) Flow Rate (cfm) Flow Rate (lpm) Filter Efficiency Operating Temp. Range (°F) Operating Temp. Range (°C)
DC-XD-6 6.5 / 165 5.1 / 129.5 1 1/2″ x 16 UN female thread 1.75 / 0.79 10.65 / 315 16 @ 1 psid 456 0.3µ absolute (β₀.₃≥200) -40° to 300° -40° to 149°

Model Sizing

Model Suction/Return Rate at 1 psid (gpm/lpm) Gearbox/Storage Tank Max. Volume (gal/L) Hydraulic Reservoir Max. Volume (gal/L)
DC-XD-6 120 / 456 500  / 1893  200 / 757 

Please Note: This is intended as a general guideline for sizing only; other considerations, such as: humidity level, frequency of air flow, ambient temperatures, and chemical compatibility are very important in sizing a breather properly. Larger applications and special circumstances typically require the most thorough analysis. Please contact Des-Case for assistance in sizing a breather.

Did You Know...

Adapters

Part Number Description
DC-DSA-10 1 ” NPT Threaded Adapter for DC-XD-6
DC-DSA-17 3/4″ NPT Threaded Adapter for DC-XD-6
DC-XDVA-12M 3/4″ NPT Vent Valve Adapter for DC-XD-6
DC-XDVA-16M 1″ NPT Vent Valve Adapter for DC-XD-6

Features

By the Numbers

XD Desiccant Breather Cutaway1–Quad Check Valves
Check-valves provide system pressurization, protecting system integrity and extending product life.

2–Filter Element
ePTFE filter removes airborne contamination to 0.3-micron absolute. Stops free water.

3–Water Vapor Adsorbent
Color-indicating silica gel adsorbs water from incoming air. Replace when color changes from blue to pink.

4–Filter Element
Second particulate filter element protects against migration of desiccant.

5–Visual Indicator
Windows on two sides of breather allow for easy monitoring of desiccant.

6–Rugged Housing
Constructed from a PC/PBT alloy that maximizes chemical compatibility at the surface and impact resistance at the core.

7–Foam Pad
Foam filter captures any oil mist and disperses incoming air evenly over filtration and drying areas.

8–Integrated Standpipe
Resilient construction provides durability and allows oil mist to coalesce and drain back into the reservoir.

 

Applications

  • Harsh Environments
  • Mobile & Off-Road Equipment
  • Hydraulics – Wash Downs
  • High Vibration/Impact
  • Nautical Applications

Breather Sizing Wizard